New Baltimore calls often come from homes near the lake or off Green Street, built in the 1950s through the 1970s, with a mix of one pipe and two pipe steam. Lake Saint Clair keeps these basements damp, so we start on the water side of the boiler. Let's take a look at the automatic feeder and how often it's running.
A feeder that runs every day is telling you the boiler is losing water somewhere. We check three places in order: the wet return along the floor, the Hartford Loop connection, and the boiler sections themselves. We also look upstairs for steam leaking at radiator valves or spitting vents. Lost steam is lost water, and the feeder just keeps covering for it.
Next we test the relief valve and look for corrosion on its outlet pipe. We check the low water cutoff by blowing it down and making sure the burner drops out. If it doesn't, we stop there and fix that first. A boiler that can run dry is a safety problem before it is a comfort problem.
Then we deal with the complaint the homeowner called about, often a cold room or a boiler that runs and runs while the house stays chilly. We check main vents, the pressure setting and the gas burner. Every finding goes on paper with photos of anything rusted, so the homeowner sees what the lake is doing to their piping.